Skip to resume
Amarat, LLCConcorde LLC
← All team members

CONCORD LLC TEAM / CONCORDE LLC

Venkata K. Pendurthi, PE

Relay Settings and System Studies Lead

Discuss a project →

Professional Profile

Power system protection and control application and relay settings engineer with more than 18 years of protection, control and relay settings experience, more than 2 years of distribution design and 2 years of research. Experience includes misoperation analysis and remedial actions; NERC regulatory compliance for protection and control (CIP, PRC-025, PRC-023, PRC-001/PRC-027, PRC-026, PRC-005); managing engineering teams, budgets, bidding and delivery; and training and mentoring young engineers in power system protection.

Selected Experience

Principal Engineer

Engineering practice | Brandon, MS | Since September 2021

Consultancy on protection and control applications; development and quality checking of relay settings for transmission, distribution and generation interconnections.

Principal Engineer

Contractor for Entergy and Southern Company | March 2016 to December 2021

  • Expert opinion on the technical aspects of power system protection and control schemes.
  • New and improved relay settings standards; settings for high-profile non-standard jobs.
  • Mentorship and leadership of less experienced and new-hire engineers; responsible for the group’s budget, efficiency and quality.

Senior Protection and Control Engineer; Electrical Engineer II, III

CompuSharp Inc., Jackson, MS, January 2012 to February 2016 | IK Power System Solutions Inc., Jackson, MS, May 2010 to January 2012

  • Short-circuit and coordination studies and relay settings for transmission lines, transformers, capacitor banks, bus protection and breakers at HV and EHV levels, on Schweitzer, GE, Westinghouse, ERL and electromechanical relays.
  • Project execution plans, facility study documents and labor estimates for capital and grid projects; scope documents and relay impact studies.
  • Test plans and support for field engineers during relay testing; settings support for planned and unplanned outages.
  • Settings and documents in compliance with NERC and SERC requirements (PRC-025, PRC-023, PRC-001, PRC-005, FAC-009).
  • ASPEN OneLiner and CAPE model creation and review; arc flash studies with PPE, labels and safety procedures; clearing time analysis for system stability.

Smart Grid Engineer

CompuSharp Inc., Jackson, MS | October 2009 to April 2010

Developed SCADA systems in Fortran (EMS SCADA) and CIM models in XML/UML.

Graduate Research Assistant

Mississippi State University | February 2008 to November 2009

Developed a fuzzy inference algorithm to mitigate uncertainty in meter data, combined with a genetic-algorithm reconfiguration system in MATLAB.

Electrical Design Engineer (Buildings and Factories)

Larsen & Toubro Limited, Chennai, India | July 2006 to November 2007

Complete electrical designs for commercial, industrial and IT office buildings: load estimation, transformer and backup-generator sizing, cable schedules, lighting, power flow and short-circuit calculations, and arc flash studies. Supervised the CAD drafting team and prepared scope, design basis, bills of materials and technical specifications.

Qualifications as supplied November 1, 2026. Experience includes work with prior employers. Project roles, availability and current professional registrations are confirmed for each engagement.